Water District approves $2.9 million grant application for PFAS treatment design
Commissioners also authorize plastic pipe for new mains and discuss a blending proposal to avoid a $40 million plant.

LUNENBURG — The Water District of Lunenburg voted to authorize Time Bond to apply for a $2,898,000 Emerging Contamination Grant from MassDEP to fund the planning and design of a PFAS treatment system 118:30. The board also approved the use of C-909 plastic pipe for water main projects on Brown Road and Shirley Road, a decision that could reduce construction costs compared to traditional ductile iron 14:21.
- Approve minutes of September 23 meeting — Approved 3:16
- Allow use of C-909 plastic pipe for Brown Road and Shirley Road projects — Approved 14:21
- Allow plastic for service lines with tracer wire — Approved 16:13
- Authorize Time Bond to apply for $2,898,000 Emerging Contamination Grant — Approved 118:30
- Move November meetings to Nov 4 and 18 — Approved 129:31
- Adjourn meeting — Approved 143:30
The meeting in a minuteVideo brief · 0:58Watch
More briefs →Commissioner Bill Emke presented a detailed proposal to meet the state’s 4 parts per trillion PFOA limit without immediately building a treatment plant, which he estimated would cost approximately $40 million in capital expenses and $200,000 annually to operate 31:26. Emke’s model suggests blending water from the Lancaster well field with the Keating well could lower contaminant levels below the threshold, though several commissioners expressed concern about the long-term viability and capacity of this approach 73:45.
The board discussed a proposal to purchase water from the Townsend Water District, which committed to supplying 500,000 to 600,000 gallons per day at a rate between $9.54 and $12.73 per 100 cubic feet 107:33. Commissioners noted that while this provides a short-term solution, the infrastructure costs for connection and pumping remain significant and were not fully detailed in the meeting 111:46.
PFAS Treatment and Blending Proposal
Emke’s presentation focused on using 2020 pumping data to model a system where Well Number 5, which has PFOA levels around 8 parts per trillion, is shut off, and its volume is replaced by water from the Keating well, blended with the Lancaster wells 35:52. He proposed pumping rates of about 125 gallons per minute for Well 1, 160 for Well 2 and 150 for Well 4, which he believes would keep the blended water below the 4 parts per trillion limit 47:52.
Commissioners questioned the reliability of the model, noting that the district’s maximum daily usage in the last 10 years was 1.4 million gallons, while while the proposed system might struggle to meet peak days of about 1.2 million gallons (the maximum ever was 1.4 million), against an average summer demand of about 920,000 gallons per day 81:10. One commissioner argued that the proposal is a 'patch' for a bad tank and that the district should move toward a treatment plant to ensure long-term safety 74:15.
The board agreed to meet with MassDEP on Wednesday, October 28, to seek guidance on whether blending would be accepted as a long-term compliance strategy or only as an interim measure 128:51. They also decided to move their November meetings to the 4th and 18th to avoid the Veterans Day holiday 129:31.
Pipe Specifications and Infrastructure
The board approved a motion to allow C-909 plastic pipe for the Brown Road and Shirley Road projects, with the condition that the superintendent review the final plans 14:21. A subsequent motion allowed plastic for service lines provided a tracer wire is installed to aid in future locating 16:13. Commissioners noted that plastic is cheaper and more flexible than ductile iron, though some expressed concern about surge issues in areas like Pleasant Street 9:05.
Staff reported on several infrastructure costs, including a $18,925 quote to clean and service the Keating well and a $53,406 quote for the four-well field at Well Number 5 131:45. A burnt variable frequency drive requiring repair was cited at a cost of $8,602 133:44. The board also discussed a $12,000 quote for a resident meter monitoring platform, which would allow customers to track usage and detect leaks 135:59.
- Approved the minutes of the September 23 meeting 3:16.
- Waived finance charges for the Lunenburg Public Schools due to a billing error, provided the underlying bill is paid 140:02.
- Noted a $75 turn-on fee was charged to a resident after a shutoff, with the RAFT program covering the remaining balance 21:14.
- The proposed water purchase rate from Townsend is between $9.54 and $12.73 per 100 cubic feet, with an average of $11.14.
- The current daily average water usage is approximately 450,000 to 500,000 gallons.